- Not available
TC charger 3,3kW CAN, 144V (50-198V) - 23A
3.3kW TCCharger HK-J-H198-23 is designed for electric vehicle LiFePO4/lithium and battery management system interface. It's a charger with high efficiency, high stability, small size, small volume and high protection grade(IP67).
Connectors included.
1. Up to 95% power efficiency and more than 93% Full Load efficiency
Basic Model |
Nominal Voltage |
Output voltage Range |
Output current -Maximum |
(CV Setting Range) |
(Max CC setting) |
||
HK-J-H99-40 |
72V |
18-99V |
40A |
HK-J-H116-40 |
84V |
25-116V |
40A |
HK-J-H132-32 |
96V |
34-132V |
32A |
HK-J-H198-23 |
144V |
50-198V |
23A |
HK-J-H440-10 |
312V |
110-440V |
10A |
HK-J-H650-06 |
540V |
170-650V |
6A |
Technical Data | |
AC Input Voltage Range | AC90V~AC265V |
AC Input Frequency | 45~65 Hz |
AC Power Factor | ≥0.98 |
Full Load Efficiency | ≥93% |
Mechanical Shock & | Conformance to |
Vibration Resistance Level |
10-25Hz Amplitude 1.2mm, 25-500Hz 30m/s2, 8hrs per direction |
Environmental Enclosure | IP67 |
Operating Temperature | -35℃~+85℃ |
Storage Temperature | -55℃~+100℃ |
Mechanical Dimensions(mm) | 239(L)*135(W)*125(H) |
Net Weight | 6.4kg |
Protection Function | |
Input Over-voltage Protection | AC270±5V |
Input Under-voltage Protection | AC85±5V |
Output Over-voltage Protection | Stop the output when exceeds +1% of the maximum output voltage |
Output Under-voltage Protection | Stop the output when below -5% of the minimum output voltage |
Output Over-current Protection | Stop the output when exceeds +1% of the maximum output current |
Over-temperature Protection | Power down from 85℃ and turn off at 90℃ |
Short-circuit Protection | Stop Output |
Battery Reverse Connect Protection | Fuse Burn-out |
Ground Protection | ≤100mΩ |
CAN communication Protection | Automatically stop the output when CAN communication fails |
Power-off Protection | Yes |
LED Status Indicator | |
1)Initial State | Red Off Green Off Red Off Green Off Red Off Green Off Red Off Green Off |
2)Charge State | Red Off Red Off Red Off Red Off Red Off Red Off Red Off Red Off |
3)Stand-by State | Green Off Green Off Green Off Green Off Green Off Green Off Green Off Green Off |
4)Fault Checking | Red Green………………....…………Wrong Battery |
Green Red…………………....………Wrong Input Voltage | |
Green Red Green……………..……Internal Temperature Protection | |
Green Red Green Red…………...Wrong Hardware | |
Red Green Red…………………..…Wrong Communication | |
Red Green Red Green……………Other error status word error |
Question & Answer:
Q :
Hello! Is there any way to buy connectors separately? If not, can you provide me a company that could sell these. I could not find any information about these connectors from Google.
A: Hello, usually we don't have spare connectors for this model. Is an old generation and is no longer manufactured. I'm going to ask warehouse if they have a spare connectors kit and will reply on e-mail. Thanks!
George @EVShop